480B High-precision Power Meter

Highlight:

If connected with the integrated thermal analyzer, the load power meter can provide multi-dimensional data of voltage, current, power and temperature at the same time for comprehensive analysis, such as the relationship between temperature and power of components, heating conditions under different voltages during heating material analysis, etc. Dianyang Technology has completed the alignment work, and is able to provide 480B High-precision Power Meter and Dingyang DC Load Analyzer. The design of 480B adopts an advanced 32-bit high-speed processor and a dual-loop 24 bit AD converter, with characteristics of high precision, wide dynamic range, as well as compact and dexterous structure. It is a new-generation touch screen digital power analyzer. Its RS232/485, USB, Ethernet and other interfaces can satisfy the different demands of users for communication testing.


Product Details

Download

♦ Overview

If connected with the integrated thermal analyzer, the load power meter can provide multi-dimensional data of voltage, current, power and temperature at the same time for comprehensive analysis, such as the relationship between temperature and power of components, heating conditions under different voltages during heating material analysis, etc.

Dianyang Technology has completed the alignment work, and is able to provide 480B High-precision Power Meter and Dingyang DC Load Analyzer.

The design of 480B adopts an advanced 32-bit high-speed processor and a dual-loop 24 bit AD converter, with characteristics of high precision, wide dynamic range, as well as compact and dexterous structure. It is a new-generation touch screen digital power analyzer. Its RS232/485, USB, Ethernet and other interfaces can satisfy the different demands of users for communication testing.

480B High-precision Power Meter

♦ Basic technical indicators:

Technical indicators Technical parameters
Bandwidth DC: (0.5 - 1) KHz
Input mode Floating input is adopted for both voltage and current
Display update The update cycle can be set between 0.1 and 5 seconds
Line filtering Cut-off frequency of 500Hz
A/D conversion The sampling period is about 70μS, 24 bit; simultaneous sampling of voltage and current is supported
Input impedance The voltage input impedance is about 2MΩ, the current input impedance is about 0.5Ω at low level and about 4MΩ at high level.
The input impedance of the signal input terminal of the external sensor changes with the input voltage.
For example, when the input voltage is 10V, the input impedance is about 100kΩ; and when the input voltage is 2V, the input impedance is about 20kΩ.
Zero calibration method It will calibrate to zero whenever the measuring range is changed or the measuring mode is changed.
Measuring mode True RMS, voltage mean, AC, DC
Overall power consumption < 10VA
Working power supply AC: 100V - 240V  45-440Hz; DC: 100V - 300V
Communication interface USB (standard), RS-232/485 (standard), Ethernet (optional)

♦ Accuracy parameters:

Parameters Measuring range Error Minimum resolution
Voltage 0.5V~600V DC              ±(0.1% of the reading + 0.2% of the range)0.5Hz ≤ f < 45Hz   ±(0.1% of the reading + 0.2% of the range)

45Hz ≤ f < 66Hz   ±(0.1% of the reading + 0.1% of the range)

66Hz ≤ f < 1kHz   ±(0.1% of the reading + 0.2% of the range)

0.001V
Current 0.05mA~45A 0.01mA
Active power U*I*PF DC              ±(0.1% of the reading + 0.2% of the range)0.5Hz ≤ f < 45Hz   ±(0.3% of the reading + 0.2% of the range)

45Hz ≤ f < 66Hz   ±(0.1% of the reading + 0.1% of the range)

66Hz ≤ f < 1kHz   ±(0.2% of the reading + 0.2% of the range)

0.001mW
Power factor 0.01~1 0.5Hz ≤ f ≤ 66Hz       ±0.0166 Hz < f ≤ 1kHz        ±0.02 0.001
Frequency 0.5Hz~1KHz 0.1% 0.001Hz
Electric energy accumulation 0~999999MWh0~-99999MWh DC              ±(0.1% of the reading + 0.2% of the range)0.5Hz ≤ f < 45Hz   ±(0.3% of the reading + 0.2% of the range)

45Hz ≤ f < 66Hz   ±(0.1% of the reading + 0.1% of the range)

66Hz ≤ f < 1kHz   ±(0.2% of the reading + 0.2% of the range)

0.0001mWh