page_banner

Normal Temperature Scale TS-44

Highlight:

This is an optional accessory for TA series

As a product provided by Dianyang Technology, Normal temperature scale TS-44 is able to provide standard and accurate temperature value, and can be used together with TA Series Integrated Thermal Analyzer for it to calibrate the temperature accuracy under a high gain of (-10℃ – 120℃). With a factory standard temperature value of 50℃, the temperature scale is able to detect whether there is any deviation in the temperature measurement results of TA Thermal Analyzer, or be used in the real-time temperature calibration by TA Thermal Analyzer to ensure that its temperature deviation is not greater than ±0.5℃.


Product Details

Specification

Download

♦ Overview

This is an optional accessory for TA series

As a product provided by Dianyang Technology, Normal temperature scale TS-44 is able to provide standard and accurate temperature value, and can be used together with TA Series Integrated Thermal Analyzer for it to calibrate the temperature accuracy under a high gain of (-10℃ - 120℃). With a factory standard temperature value of 50℃, the temperature scale is able to detect whether there is any deviation in the temperature measurement results of TA Thermal Analyzer, or be used in the real-time temperature calibration by TA Thermal Analyzer to ensure that its temperature deviation is not greater than ±0.5℃.

♦ specification

Technical indicators Technical parameters Technical indicators Technical parameters
Temperature standard Single temperature of 50 ℃ Working temperature 0°C-50°C
Target size (38* 38)mm Working humidity ≤90%RH
Target emissivity 0.97±0.02 Temperature adjustment Temperature regulation of USB interface
Temperature stabilization time 40 seconds Weight 26g
Stability < ±0.1℃ (±0.18℉) Power consumption 1.2W
Power supply DC 12V Device size (40* 40* 20)mm
Temperature error ±0.5℃    

  • Previous:
  • Next:

  • Technical indicators Technical parameters Technical indicators Technical parameters
    Temperature standard Single temperature of 50 ℃ Working temperature 0°C-50°C
    Target size (38* 38)mm Working humidity ≤90%RH
    Target emissivity 0.97±0.02 Temperature adjustment Temperature regulation of USB interface
    Temperature stabilization time 40 seconds Weight 26g
    Stability < ±0.1℃ (±0.18℉) Power consumption 1.2W
    Power supply DC 12V Device size (40* 40* 20)mm
    Temperature error ±0.5℃    
    Write your message here and send it to us