page_banner

New upgraded PCB thermal camera analyzer CA-30 and CA-60 for lab and R&D application

Highlight:

◎Online continuous temperature measurement;

◎Up to 640×512 high-definition thermal imaging;

◎Temperature Measuring Range: -20℃~550℃;

◎25um target objects can be observed with macro-lens;

◎CA software records and analyzes full radiometric thermal video files with temperature data

◎Different emission rates are set for multiple areas;

◎Syncronize 3 curves: temperature, voltage and current;

◎Type C connection to computer with scientific research analysis software;


Product Details

Application

Specification

Download

Sticking to your belief of “Creating solutions of high quality and generating buddies with people from all around the world”, we always put the fascination of customers to start with for New upgraded PCB thermal camera analyzer CA-30 and CA-60 for lab and R&D application, We promise to try our greatest to provide you with good quality and productive services.
Sticking to your belief of “Creating solutions of high quality and generating buddies with people from all around the world”, we always put the fascination of customers to start with for hardware design, Thermal Camera, thermal distribution, Thermal Imaging, thermal map, thermal test, Our company always concentrate on the development of the international market. We have a lot of customers in Russia , European countries, the USA, the Middle East countries and Africa countries. We always follow that quality is foundation while service is guarantee to meet all customers.

Overview

DytSpectrumOwl CA-30/60 Scientific-Research Grade Thermal Analyzer (“CA”) integrates imaging, temperature measurement, analysis and data collection, providing effective test data for education, scientific research, industry inspection.

CA supports the use of macro-lenses, and has a unique stable support, a rapid lens change structure, and professional scientific research software to solve users’ problems of comprehensive data analysis, effective temperature measurement analysis of different materials, scene restoration analysis of files with temperature data, etc., providing users with a simpler and more flexible experience.

 

TRANSLATE with x
English

Arabic Hebrew Polish
Bulgarian Hindi Portuguese
Catalan Hmong Daw Romanian
Chinese Simplified Hungarian Russian
Chinese Traditional Indonesian Slovak
Czech Italian Slovenian
Danish Japanese Spanish
Dutch Klingon Swedish
English Korean Thai
Estonian Latvian Turkish
Finnish Lithuanian Ukrainian
French Malay Urdu
German Maltese Vietnamese
Greek Norwegian Welsh
Haitian Creole Persian  


 
TRANSLATE with
COPY THE URL BELOW

Back


EMBED THE SNIPPET BELOW IN YOUR SITE

Enable collaborative features and customize widget: Bing Webmaster Portal
Back

Analysis mode

IC and Circuit board analysis mode

Analysis mode of E-cigarette atomizer

Multi-dimensional analysis mode

Analysis mode of material thermal capacity

Defect analysis mode

Product features

Adopting a high quality thermal imaging detector; wide temperature measurement range: -20℃~550 ℃

asva (4)
avab (2)

Angle adjustment frame, with the adjustment mode designed according to experimenters’ custom

Large angle wide-angle and dual micro-lens can be quickly changed

asva (6)
asva (5)

Target objects under test of different sizes are considered; the base plate can be disassembled or spliced

Direct connection via USB; image transmission without delay; simple connection and ease of used

asva (1)
avab (3)

Can be connected to power analyzers and temperature sensors for multi-dimensional analysis of ambient temperature, voltage, current and temperature data

With a micro-lens, temperature changes of φ=25um small objects can be observe

avab (4)
avab (5)

With the professional analysis software, smaller details and richer contents can be observed, recorded and detected

High resolution image; unique DDE algorithm; observation of very small objects

avab (6)
avab (7)

High resolution image; unique DDE algorithm; observation of very small objects

Dianyang has launched the new upgraded thermal camera CA-30 and CA-60, with 384×288 and 640×512 resolution, advanced macro lens, its capable to provide strict inspection of IC level small components.

Packed in rugged suitcase and combine powerful thermal analysis software, CA-30 and CA-60 will be your most helpful tools to fix hardware problems.

Our company always concentrate on the development of the international market. We have a lot of customers in European countries, the USA, the Middle East countries and Africa countries. We always follow that quality is foundation while service is guarantee to meet all customers.


  • Previous:
  • Next:

  • Test and analysis of thermally conductive materials Different temperature measurement ranges are set and the background is removed to observe the process of thermal conduction of materials.

    acvdas (1)

    Analysis of thermal fibers, integrated chips and other fine materials The size of the real object observed in picture-in-picture mode is (1.5*3)mm, and 25um gold wires or smaller target objects in the chip can be observed with the micro-lens.

    acvdas (2)

    Temperature control analysis of E-cigarette Quickly tracking the heating rate and temperature of the atomizer

    acvdas (3)

    Thermal design analysis of circuit board When the circuit board chip heats up, users can check the components affected by the heat to adjust the layout.

    acvdas (4)

    Heat dissipation analysis of materials Video files with temperature data can be recorded for unlimited time, which can be used to repeatedly analyze the heat dissipation performance of materials and record reliability data.

    acvdas (5)

    Quality analysis of products and parts
    Detecting temperature changes on a real-time basis, tracking the maximum temperature, minimum temperature and average temperature, and giving overtemperature alarms during automatic product processing.

    acvdas (6)

    Circuit board pulse heating analysis The thermal analyzer can quickly capture the occasional pulse heat emitted by some components on the circuit board due to failure.

    acvdas (7)

    Analysis of temperature change process of heating materials under different voltages and currents The heating rate, heating efficiency and heating temperature of heating wires, heating films and other materials under different voltages and currents can be quantitatively analyzed.

    acvdas (8)

    Parameter

    CA-30

    CA-60 

    IR Resolution

    384*288

    640*512

    NETD

    <50mK@25℃,f#1.0

    <50mK@25℃,f#1.0

    Spectral Range

    8~14um

    8~14um

    FOV

    29.2°X21.7°

    48.7°X38.6°

    IFOV

    1.3mrad

    1.3mrad

    Image Frequency

    25Hz

    25Hz

    Focus mode

    Manual focus

    Manual focus

    Working temperature

    -10℃~+55℃

    -10℃~+55℃

    Macro-lens

    Support

    Support

    Measurement and Analysis

    Object Temperature Range

    -20℃~550℃

    -20℃~550℃

    Temperature measurement method

    Highest Temp.,Lowest Temp. and Avg Temp.

    Highest Temp.,Lowest Temp. and Avg Temp.

    Temperature measurement accuracy

    ±2 or ±2% for -20℃~120℃, and ±3% for 120℃~550℃

    ±2 or ±2% for -20℃~120℃, and ±3% for 120℃~550℃

    Measuring distance

    (4 ~ 200)cm

    (4 ~ 200)cm

    Temperature correction

    Automatic

    Automatic

    Separate emissivity set 

    Adjustable within 0.1-1.0

    Adjustable within 0.1-1.0

    Image file

    Full-temperature JPG thermogram (Radiometric-JPG)

    Full-temperature JPG thermogram (Radiometric-JPG)

    Video file

    MP4

    MP4

    Full Radiometric Thermal Video file

    dyv format, (opened with CA’s software)

    dyv format, (opened with CA’s software)

     

    User Guide of CA Series Scientific-Research GradeThermal Analyzer

    CA Series Scientific-Research Grade Thermal Analyzer product specification

    DytSpectrumOwlsetup

     

     
     
    翻译为
     
     
     
     